Categories: 罗克韦尔

Studio 5000 V32.00英文版只含英文

New features

Produce-Consume axis over EtherNet/IP

The produce-consume axis over EtherNet/IP lets users select a produced axis controller type that supports AXIS_CONSUMED tags on a remote chassis to be consumed by one or more axes. The participating controllers communicate using EtherNet/IP protocol. The communication path to the producer of a consumed axis tag cannot cross ControlNet. Produce-consume axis over EtherNet/IP is available only on CompactLogix 5380, Compact GuardLogix 5380, CompactLogix 5480, ControlLogix 5580, and GuardLogix 5580 controllers.

Function Block functions

Function Block functions are similar to Function Block instructions but do not require backing tags, require less memory, execute more quickly, and take up less canvas space in a function block diagram. Function Block functions are available only on CompactLogix 5380, Compact GuardLogix 5380, CompactLogix 5480, ControlLogix 5580, and GuardLogix 5580 controllers.

Data Exchange Toolkit

Users can exchange data files that represent Rockwell Automation devices in the automation system. Use files produced in a tool such as EPLAN Electric P8 or AutoCAD Electrical to create a Logix Designer project file that represents a controller-centric subset of the system. Create this project file without having to manually add, name, or recreate high-level configuration of the associated devices.

Users can import or export hardware diagrams to or from a Web Ontology Language (OWL) or AutomationML (AML) file type to share data between different software applications and Logix Designer Professional Edition.

CIP Security fault codes

New CIP Security fault codes report CIP security session errors.

Ethernet Port Fault minor fault

A new EtherNet/IP data storm fault reports network traffic on an Ethernet port.

Data integrity loss minor fault

A new data integrity loss minor fault reports that a potential problem exists with the module’s input/output size and/or the module does not support start and end integrity.

Operating system and service pack compatibility:

Windows® 10 Professional (64-bit) version 1803

Windows 7 Professional (64-bit) with Service Pack 1

Windows 8.1 Professional (64-bit) with April 2014 Update Roll-up

Windows Server 2008 R2 Standard Edition with Service Pack 1

Windows Server 2012 R2 Standard Edition

Windows Server 2016

These prerequisite software are required with this version of Logix Designer application and will be installed with this release:

FactoryTalk® Services Platform v6.10.00

FactoryTalk® Activation Manager v4.03.00

FactoryTalk® Linx™ v6.10.00

RSLinx Classic v4.10.00

Studio 5000 V32.00英文版下载链接

微信搜索或扫码关注
学自动化 公众号
回复  000590
获取资源下载链接
xuezdh